首页 / 院系成果 / 成果详情页

The development of a new three-channel self-pressurized wrist pulse acquisition system  期刊论文  

  • 编号:
    93212dac-cdec-4ead-82b3-391774e0c69b
  • 作者:
    Zhou, KanHeng;Peng, Qian;Xia, ChunMing;Wang, YiQin(王忆勤)
  • 作者单位:
    (1) School of Mechanical and Power Engineering, East China University of Science and Technology, No. 130 MeiLong Road., Shanghai, China (2) School of Basic Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai, China
  • 语种:
    英文
  • 会议名称:
    BIODEVICES 2015 - 8th International Conference on Biomedical Electronics and Devices, Proceedings; Part of 8th International Joint Conference on Biomedical Engineering Systems and Technologies, BIOSTEC 2015
  • 会议地点:
    Lisbon, Portugal
  • 收录:
  • 摘要:

    A new three-channel self-pressurized pulse acquisition system based on the principle of wrist pulse diagnosis in Traditional Chinese Medicine (TCM) was introduced in this paper, including the hardware and the software design of this acquisition system. This acquisition system can not only get three-channel wrist pulse waveforms under the best pulse taking force through the automatic pressure control module composed of stepper motors and ball screw pairs, but also simulate the process of the three regions and nine pulsetakings wrist pulse diagnosis in TCM. Besides, this acquisition system also can real-timely display and store three-channel wrist pulse waveforms. It can been seen that this wrist pulse acquisition system solved the problem that only the pulse waveforms in Guan region of the wrist can be detected, which does most of the existent pulse acquisition systems have. The system provided a user-friendly flexible sample collection platform, laid the foundation for analyzing the multi-channel wrist pulse waveforms and pushed forward the development of the standardization of wrist pulse waveforms and the objectification of wrist pulse diagnosis in TCM.

  • 推荐引用方式
    GB/T 7714:
    Zhou Kan-Heng (1),Peng Qian (2),Xia Chun-Ming (1), et al. The development of a new three-channel self-pressurized wrist pulse acquisition system [J].BIODEVICES 2015 - 8th International Conference on Biomedical Electronics and Devices, Proceedings; Part of 8th International Joint Conference on Biomedical Engineering Systems and Technologies, BIOSTEC 2015,2015:23-28.
  • APA:
    Zhou Kan-Heng (1),Peng Qian (2),Xia Chun-Ming (1),Wang Yi-Qin (2).(2015).The development of a new three-channel self-pressurized wrist pulse acquisition system .BIODEVICES 2015 - 8th International Conference on Biomedical Electronics and Devices, Proceedings; Part of 8th International Joint Conference on Biomedical Engineering Systems and Technologies, BIOSTEC 2015:23-28.
  • MLA:
    Zhou Kan-Heng (1), et al. "The development of a new three-channel self-pressurized wrist pulse acquisition system" .BIODEVICES 2015 - 8th International Conference on Biomedical Electronics and Devices, Proceedings; Part of 8th International Joint Conference on Biomedical Engineering Systems and Technologies, BIOSTEC 2015(2015):23-28.
浏览次数:73 下载次数:0
浏览次数:73
下载次数:0
打印次数:0
浏览器支持: Google Chrome   火狐   360浏览器极速模式(8.0+极速模式) 
返回顶部